Shopping Cart
Shopping Cart

Ruijie RG-S2910-24GT4SFP-UP-H(V3.0)

฿70,200.00

ราคาอาจมีการเปลี่ยนแปลงได้ กรุณาสอบถามราคาก่อนสั่งซื้ออีกครั้ง

Ruijie RG-S2910-24GT4SFP-UP-H(V3.0)

Highlight Feature

  • High-power remote power supply, allowing energy to pass through the network.
  • Network cable and wire in one, simple deployment.
  • From equipment to power supply to network, the three-dimensional integration ensures security and stability.
  • Remote restart for easy O&M.
รหัสสินค้า RG-S2910-24GT4SFP-UP-H(V3.0) หมวดหมู่ ,

รายละเอียดเพิ่มเติม

RG-S2910-24GT4SFP-UP-H(V3.0) Ruijie

Specifications

Hardware Specifications

Hardware Specifications RG-S2910-24GT4SFP-UP-H(V3.0) RG-S2910-24GT4XS-UP-H(V3.0)
Ports
Fixed service port 24 x 10/100/1000M electrical ports supporting auto negotiation + 4 x 1GE SFP ports 24 x 10/100/1000M electrical ports supporting auto negotiation + 4 x 10GE/1GE SFP+ ports
System
Switching capacity 56 Gbps 128 Gbps
Packet forwarding rate 42 Mpps 96 Mpps
Dimensions and Weight
Dimensions (W x D x H) 440 mm x 260 mm x 44 mm (17.32 in. x 10.24 in. x 1.73 in.) 440 mm x 260 mm x 44 mm (17.32 in. x 10.24 in. x 1.73 in.)
Power Supply and Consumption
Rated input voltage AC input: rated voltage range 100 V to 240 V, frequency 50/60 Hz
Maximum input voltage AC input: rated voltage range 90 V to 264 V, frequency 50/60 Hz
Input voltage High voltage DC (HVDC) input: input voltage range 192 V to 290 V
PoE power supply 24 x electrical ports supporting PoE and PoE+ 24 x electrical ports supporting PoE and PoE+
Maximum output power of a PoE interface Maximum PoE/PoE+ output power: 370 W Maximum PoE/PoE+ output power: 370 W
Environment and Reliability
Fan monitoring Fan speed adjustment and fault alarms
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature –40°C to +70°C (–40°F to +158°F)
Operating humidity 10% to 90% RH
Storage humidity 5% to 95% RH
Operating altitude –500 m to +5000 m (–1640.42 ft to +16404.20 ft)

Software Specifications

Software Specifications RG-S2910-24GT4SFP-UP-H(V3.0) RG-S2910-24GT4XS-UP-H(V3.0)
VLAN 4K VLANs

Interface-based VLAN assignment

MAC address-based VLAN assignment

Protocol-based VLAN assignment

Private VLAN

Voice VLAN

IP subnet-based VLAN

GVRP

QinQ Basic QinQ

Selective QinQ

ACL Standard IP ACL

Extended IP ACL

Extended MAC ACL (hardware ACL based on the source MAC address, destination MAC address, and optional Ethernet type)

Time range-based ACL

Expert-level ACL (hardware ACL based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port ID, protocol type, and time range)

ACL 80

IPv6 ACL

Global ACL

ACL redirection

QoS Rate limiting on an interface based on the ingress or egress

Flow-based rate limiting on the ingress or egress

802.1p/DSCP/ToS traffic classification

Eight priority queues per interface

SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR, and RED/WRED scheduling

Mirroring Common service interfaces and aggregate interfaces that can be configured as source and destination interfaces of mirroring

1:1, 1:N, N:1, and flow-based local and remote mirroring

RSPAN and ERSPAN

Cross-device traffic mirroring

DHCP DHCP server

DHCP client

DHCP snooping

DHCP relay

IPv6 DHCP snooping

IPv6 DHCP client

IPv6 DHCP relay

Layer 2 protocols IEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1p, IEEE 802.1x, IEEE 802.3ab, IEEE 802.1Q (GVRP), IEEE 802.1d, IEEE 802.1w, IEEE 802.1s IEEE 802.1s, and IGMP snooping v1/v2
Security 3-tuple binding (IP address, MAC address, and interface)

3-tuple binding (IPv6 address, MAC address, and interface)

Invalid MAC address filtering

Interface- and MAC address-based 802.1X authentication

MAC address bypass authentication (MAB)

Portal and Portal 2.0 authentication

ARP check

DAI

Trusted ARP

ARP spoofing prevention

Broadcast or multicast storm suppression

Unknown multicast suppression and multicast bandwidth suppression

Hierarchical management and password protection

RADIUS and TACAS+

AAA (IPv4/IPv6) for device login management

SSH and SSHv2.0

BPDU guard

IP source guard

CPP and NFPP

Port protection

Cable diagnostics Cable detection
Energy Efficient Ethernet (EEE) IEEE 802.3az-compliant EEE: When EEE is enabled, power consumption of interfaces is significantly reduced.
Port sleeping Port sleeping
PoE IEEE 802.3af, IEEE 802.3at,

Automatic and energy-efficient power supply management modes

Warm start to implement uninterrupted power supply

Interface priority

Compatibility with non-standard PDs

Scheduled power-on/off of PoE interfaces

IP routing IPv4/ IPv6 static route

RIP, RIPng, OSPFv2, and OSPFv3

Routing policy

IPv6

Basic protocols

IPv6 addressing, Neighbor Discovery (ND), IPv6 ACL, ICMPv6, IPv6 ping, and IPv6 tracert
VSU features VSU

Local and remote stacking

Cross-chassis link bundling within the stack

Not supported
Zero Touch Provisioning (ZTP) CWMP (TR-069) standard protocol
Management features SNMP, CLI (Telnet/console), RMON, SSH, Syslog/debugging, NTP/SNTP, FTP, TFTP, web, and sFlow

ข้อมูลเพิ่มเติม

การรับประกัน

3ปี

รีวิว

ยังไม่มีบทวิจารณ์

มาเป็นคนแรกที่วิจารณ์ “Ruijie RG-S2910-24GT4SFP-UP-H(V3.0)”

อีเมลของคุณจะไม่แสดงให้คนอื่นเห็น ช่องข้อมูลจำเป็นถูกทำเครื่องหมาย *

LINE LOGO SVG สอบถามเพิ่มเติม