คำอธิบาย
RG-CS83-24GT4XS-P Ruijie
Specifications
Hardware Specifications
Hardware Specifications | RG-CS83-12GT4XS-P | RG-CS83-24GT4XS | RG-CS83-48GT4XS | RG-CS83-24GT4XS-P | RG-CS83-48GT4XS-P |
Interface Specifications | |||||
Fixed ports | 12 x 100M/1000M BASE-T ports
4 x 1GE/10GE SFP+ ports support PoE+ |
24 x 100M/1000M BASE-T ports
4 x 1GE/10GE SFP+ ports |
48 x 100M/1000M BASE-T ports
4 x 1GE/10GE SFP+ ports |
24 x 100M/1000M BASE-T ports
4 x 1GE/10GE SFP+ ports support PoE+ |
48 x 100M/1000M BASE-T ports
4 x 1GE/10GE SFP+ ports support PoE+ |
Fan module | 1 x fixed fan module | No fan | 1 x fixed fan module | 1 x fixed fan module | 1 x fixed fan module |
Power module | 1 x fixed power module | 1 x fixed power module | 1 x fixed power module | 1 x fixed power module | 1 x fixed power module |
Fixed management port | 1 x console, and 1 x USB 2.0 port | ||||
System Specifications | |||||
Packet forwarding rate | 78 Mpps | 96 Mpps | 132 Mpps | 96 Mpps | 132 Mpps |
Switching capacity | 104 Gbps | 128 Gbps | 176 Gbps | 128 Gbps | 176 Gbps |
MAC address table size | 16,000 | ||||
ARP table size | 4,000 | 4,000 | 4,000 | 4,000 | 4,000 |
Number of IPv4 unicast routes | 6,000 | ||||
Number of IPv4 multicast routes | 1,000 | ||||
Number of IPv6 unicast routes | 2,000 | ||||
Number of IPv6 multicast routes | 750 | ||||
Number of ACEs | Ingress: 1,750
Egress: 800 |
||||
Number of VSU members | 4 | 4 | 4 | 4 | 4 |
Dimensions and Weight | |||||
Dimensions (W x D x H) | 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) | 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) | 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) | 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) | 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
Weight | 3 kg (6.61 lbs) | 3 kg (6.61 lbs) | 3 kg (6.61 lbs) | 3 kg (6.61 lbs) | 3.75 kg (8.27 lbs) |
CPU and Storage | |||||
CPU | 1.0 GHz dual-core CPU | 1.0 GHz dual-core CPU | 1.0 GHz dual-core CPU | 1.0 GHz dual-core CPU | 1.0 GHz dual-core CPU |
Flash memory | 512 MB | 512 MB | 512 MB | 512 MB | 512 MB |
BootROM | 16 MB | 16 MB | 16 MB | 16 MB | 16 MB |
SDRAM | 1 GB | 1 GB | 1 GB | 1 GB | 1 GB |
Data packet buffer | 4 MB | 4 MB | 4 MB | 4 MB | 4 MB |
Power and Consumption | |||||
Maximum power consumption | < 35 W (non-PoE)
< 405 W (PoE full load) |
< 25 W | < 40 W | < 35 W (non-PoE)
< 405 W (PoE full load) |
< 52 W (non-PoE)
< 460 W (PoE full load) |
Maximum output power | 409 W
Maximum PoE output :370W |
25 W | 40 W | 409 W
Maximum PoE output :370W |
460 W
Maximum PoE output :405W |
Rated input voltage | 100 V AC to 240 V AC | 100 V AC to 240 V AC | 100 V AC to 240 V AC | 100 V AC to 240 V AC | 100 V AC to 240 V AC |
Maximum input voltage | 90 V AC to 264 V AC, 50 Hz to 60 Hz | 90 V AC to 264 V AC, 50 Hz to 60 Hz | 90 V AC to 264 V AC, 50 Hz to 60 Hz | 90 V AC to 264 V AC, 50 Hz to 60 Hz | 90 V AC to 264 V AC, 50 Hz to 60 Hz |
Environment and Reliability | |||||
MTBF | 24.14 years | 23.74 years | 23.85 years | 23.94 years | 22.86 years |
Primary airflow | Front-to-right and left-to-right airflow | ||||
Operating temperature | 0°C to 45°C (32°F to 113°F) | ||||
Storage temperature | –40°C to +70°C (–40°F to +158°F) | ||||
Operating humidity | 10% to 90% RH (non-condensing) | ||||
Storage humidity | 5% to 95% RH (non-condensing) | ||||
Operating noise | 27℃: < 35 dB | < 20 dB | 27℃: < 32 dB | 27℃: < 35 dB | 27℃: < 35 dB |
Interface surge protection | Power port: 6 kV(common mode)/8 kV (differential mode)
Communication port: 10 kV |
Power port: 6 kV(common mode)/6 kV (differential mode)
Communication port: 10 kV |
Power port: 6 kV(common mode)/6 kV (differential mode)
Communication port: 10 kV |
Power port: 6 kV(common mode)/8 kV (differential mode)
Communication port: 10 kV |
Power port: 6 kV(common mode)/8 kV (differential mode)
Communication port: 10 kV |
Software Specifications
RG-CS83 Series | |
Feature | Description |
Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
IEEE 802.1Q (4K VLANs) | |
Voice VLAN | |
Super-VLAN and private VLAN | |
MAC address-based VLAN, interface-based VLAN, protocol-based VLAN, and IP subnet-based VLAN | |
GVRP | |
Basic QinQ
Selective QinQ |
|
STP, RSTP, and MSTP | |
ERPS (G.8032) | |
LLDP/LLDP-MED | |
IP service | ARP |
DHCP client, DHCP relay, and DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client, DHCPv6 relay, and DHCPv6 server | |
DHCPv6 snooping | |
Neighbor Discovery (ND) and ND snooping | |
IP routing | Static routing |
RIP and RIPng | |
OSPFv2 and OSPFv3 | |
IPv4 and IPv6 VRF | |
IPv4 and IPv6 PBR | |
Multicast | IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2 snooping | |
PIM-DM, PIM-SM, and PIM-SSM | |
MSDP | |
MLD v1/v2 | |
MLD snooping v1/v2 | |
PIM-SMv6 and PIM-SSM v6 | |
ACL and QoS | Standard IP ACLs
Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection | |
Traffic rate limiting on an interface | |
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
Congestion avoidance: tail drop | |
802.1p/DSCP/ToS traffic classification
Eight priority queues per interface |
|
Security | Multiple AAA modes |
RADIUS and TACAS+ | |
Interface-based and MAC address-based 802.1x authentication | |
Web authentication | |
HTTPS | |
SSHv1 and SSHv2 | |
Global IP-MAC binding | |
Port isolation and port security | |
IP source guard | |
SAVI | |
CPP and NFPP | |
Reliability | REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP | |
BFD | |
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) | |
Hot swapping of power modules and cables | |
Fan speed adjustment
Fan fault alarm |
|
Device virtualization | Virtual Switching Unit (VSU) |
NMS and maintenance | SPAN, RSPAN |
sFlow | |
NTP and SNTP | |
FTP and TFTP | |
SNMP v1/v2/v3 | |
RMON (1, 2, 3, 9) | |
NETCONF | |
CWMP (TR-069) | |
gRPC | |
Cloud and SON | |
PoE | RG-CS83-12GT4XS-P, RG-CS83-24GT4XS-P, and RG-CS83-48GT4XS-P:
IEEE 802.3af and 802.3at Warm start Interface priority |