Description
RG-CS86-24MG4VS-UP Ruijie
Hardware Specifications
Multi-GE Switch
Hardware Specifications | RG-CS86-24MG4VS-UP | RG-CS86-48MG4VS2QXS-UPD | RG-CS86-24XMG4XS4VS-UPD | RG-CS86-12XMG4VS-UP |
Interface Specifications | ||||
Fixed port | 24 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation 4 x 10GE/25GE SFP28 ports |
48 x 100M/1000M/2.5GE/5GE electrical ports with auto-negotiation 4 x 10GE/25GE SFP28 ports + 2 x 40GE QSFP+ ports |
24 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation
4 x 1GE/10GE SFP+ ports 4 x 10GE/25G SFP28 ports |
12 x 100M/1000M/2.5GE/5GE/10GE electrical ports with auto-negotiation
4 x 10GE/25G SFP28 ports |
Fan module | 2 fixed fans | 3 modular fans | 3 modular fans | 2 fixed fans |
Power module | 1 Built-in power module | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots | 1 Built-in power module |
Fixed management port | 1 x MGMT port
1 x console port 1 x USB port |
1 x MGMT port
1 x console port 1 x USB port |
1 x MGMT port
1 x console port 1 x USB port |
1 x MGMT port
1 x console port 1 x USB port |
System Specifications | ||||
Packet forwarding rate | 327 Mpps | 625 Mpps | 565 Mpps | 327 Mpps |
Switching capacity | 440 Gbps/2.56Tbps | 840 Gbps/2.56Tbps | 760Gbps/2.56Tbps | 440 Gbps/2.56Tbps |
MAC address table size | 32,768 | |||
ARP table size | 16,000 | |||
Number of IPv4 unicast routes | 16,000 | |||
Number of IPv4 multicast routes | 4,000 | |||
Number of IPv6 unicast routes | 16,000 | |||
Number of IPv6 multicast routes | 2,000 | |||
Number of ACEs | Ingress: 2,500
Egress:1,000 |
|||
Number of VSU members | 2 | |||
Dimensions and Weight | ||||
Dimensions (W x D x H) | 442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU | 442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU | 442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU | 442 × 220 × 43.6 mm (17.40 × 29.92 × 6.89 in.) , 1 RU |
Weight | 3.65 kg (8.82 lbs) | 6.11 kg (13.47 lbs) | 6.11 kg (13.47 lbs) | 3.65 kg (8.82 lbs.) |
CPU and Storage | ||||
CPU | ARM processor, 1.25 GHz | ARM processor, 1.25 GHz | ARM processor, 1.25 GHz | ARM processor, 1.25 GHz |
Flash memory | 1 GB | 1 GB | 1 GB | 1 GB |
BootROM | 16 MB | 16 MB | 16 MB | 16 MB |
SDRAM | 1 GB | 1 GB | 1 GB | 1 GB |
Data packet buffer | 4 MB | 4 MB | 4 MB | 4 MB |
Power Supply and Consumption | ||||
Maximum power consumption | Without PoE: < 120 W (Total power consumption of all modules)
Full PoE load: < 370 W |
Without PoE: < 240 W (Total power consumption of all modules)
Full PoE load: < 1600 W |
Without PoE: < 120 W (Total power consumption of all modules)
Full PoE load: < 1650 W |
Without PoE: < 120 W (Total power consumption of all modules)
Full PoE load: < 370 W |
Maximum output power | 460W | RG-PA600I-P-F: 600 W
RG-PA1000I-P-F: 1000 W (Input Voltage: 176 V AC to 290 V AC or 190 V DC to 290 V DC) 930 W (Input Voltage: 90 V AC to 176 V AC, 176 V AC not included) |
RG-PA600I-P-F: 600 W
RG-PA1000I-P-F: 1000 W (Input Voltage: 176 V AC to 290 V AC or 190 V DC to 290 V DC) 930 W (Input Voltage: 90 V AC to 176 V AC, 176 V AC not included) |
460W |
Rated Input Voltage | Built-in power module
Rated voltage range: 100 V AC to 240 V AC |
Available model: RG-PA600I-P-F
Rated voltage range: 100 V AC to 240 V AC Available model: RG-PA1000I-P-F Rated voltage range: 100 V AC to 240 V AC |
Available model: RG-PA600I-P-F
Rated voltage range: 100 V AC to 240 V AC Available model: RG-PA1000I-P-F Rated voltage range: 100 V AC to 240 V AC |
Built-in power module
Rated voltage range: 100 V AC to 240 V AC |
Maximum input voltage | Built-in power module
Maximum voltage range: 90 V AC to 264 V AC |
Available model: RG-PA600I-P-F
Maximum voltage range: 90 V AC to 264 V AC Available model: RG-PA1000I-P-F Maximum voltage range: 90 V AC to 264 V AC |
Available model: RG-PA600I-P-F
Maximum voltage range: 90 V AC to 264 V AC Available model: RG-PA1000I-P-F Maximum voltage range: 90 V AC to 264 V AC |
Built-in power module
Maximum voltage range: 90 V AC to 264 V AC |
PoE-capable Port | Ports 1 to 24 support PoE/PoE+ and HPoE power supply Maximum output power of a HPoE-capable port: 90 W |
Ports 1 to 48 support PoE/PoE+ power supply Ports 1 to 24 support HPoE power supply Maximum output power of a HPoE-capable port: 90 W |
Ports 1 to 24 support PoE/PoE+ and HPoE power supply Maximum output power of a HPoE-capable port: 90 W |
Ports 1 to 12 support PoE/PoE+ and HPoE power supply
Maximum output power of a HPoE-capable port: 90 W |
Environment and Reliability | ||||
MTBF | 22.18 years | 27.02 years | 22.18 years | 22.18 years |
Primary airflow | Front/Left-to-rear airflow | Front/Left-to-rear airflow | Front/Left-to-rear airflow | Front/Left-to-rear airflow |
Operating Temperature | 0°C to 45°C (32°F to 113°F) | 0°C to 45°C (32°F to 113°F) | 0°C to 45°C (32°F to 113°F) | 0°C to 45°C (32°F to 113°F) |
Storage Temperature | –40°C to +70°C (–40°F to +158°F) | –40°C to +70°C (–40°F to +158°F) | –40°C to +70°C (–40°F to +158°F) | –40°C to +70°C (–40°F to +158°F) |
Operating Humidity | 10% RH to 90% RH (non-condensing) | 10% RH to 90% RH (non-condensing) | 10% RH to 90% RH (non-condensing) | 10% RH to 90% RH (non-condensing) |
Storage Humidity | 5% RH to 95% RH (non-condensing) | 5% RH to 95% RH (non-condensing) | 5% RH to 95% RH (non-condensing) | 5% RH to 95% RH (non-condensing) |
Surge Protection | 6 kV | 6 kV | 6 kV | 6 kV |
Temperature Monitoring | Temperature alarm | Temperature alarm | Temperature alarm | Temperature alarm |
Software Specifications
Software Specifications | RG-CS86-24MG4VS-UP | RG-CS86-48MG4VS2QXS-UPD | RG-CS86-24XMG4XS4VS-UPD | RG-CS86-12XMG4VS-UP |
Ethernet switching | Jumbo frame (maximum length: 9216 bytes) | |||
IEEE 802.1Q (supporting 4K VLANs) | ||||
Voice VLAN | ||||
Super VLAN, Private VLAN | ||||
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN | ||||
GVRP | ||||
Basic QinQ
Flexible QinQ |
||||
STP, RSTP, and MSTP | ||||
ERPS (G.8032) | ||||
LLDP/LLDP-MED | ||||
LACP (IEEE 802.3ad) | ||||
IP service | ARP | |||
DHCP client, DHCP relay, and DHCP server | ||||
DHCP snooping | ||||
DNS | ||||
DHCPv6 client and DHCPv6 relay | ||||
DHCPv6 snooping | ||||
Neighbor Discovery (ND) and ND snooping | ||||
IP Routing | Static routing | |||
RIP and RIPng | ||||
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 | ||||
BGP4 and BGP4+ | ||||
IPv4 and IPv6 PBR | ||||
ECMP | ||||
Multicast | IGMP v1/v2/v3, and IGMP proxy | |||
IGMP v1/v2/v3 snooping | ||||
PIM-DM, PIM-SM, and PIM-SSM | ||||
MSDP | ||||
MLD v1/v2 | ||||
MLD snooping v1/v2 | ||||
PIM-SMv6 and PIM-SSM v6 | ||||
ACL and QoS | Standard IP ACLs
Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
|||
Port traffic rate limiting | ||||
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | ||||
Congestion avoidance: tail drop, RED, and WRED | ||||
802.1p/DSCP/ToS traffic classification
Eight priority queues per port |
||||
Security | Multiple AAA modes | |||
RADIUS and TACAS+ | ||||
Port-based and MAC-based 802.1x authentication | ||||
Web authentication | ||||
HTTPS | ||||
SSHv1, SSHv2 | ||||
Global IP-MAC binding | ||||
IP source guard | ||||
SAVI | ||||
CPP and NFPP | ||||
Strict and loose RPF
uRPF ignoring default routes |
||||
Reliability | REUP, RLDP, DLDP | |||
IPv4 VRRP v2/v3 and IPv6 VRRP | ||||
BFD | ||||
GR for RIP, OSPF, BGP | ||||
1+1 power redundancy | ||||
Hot swapping of power and fan modules | ||||
Device virtualization | Virtual Switching Unit (VSU) | |||
NMS and maintenance | SPAN, RSPAN, and ERSPAN | |||
sFLOW | ||||
NTP and SNTP | ||||
FTP and TFTP | ||||
SNMP v1/v2/v3 | ||||
RMON (1, 2, 3, 9) | ||||
NETCONF | ||||
CWMP (TR-069) standard protocol | ||||
gRPC | ||||
Cloud and SON | ||||
PoE | IEEE 802.3af, 802.3at and 802.3bt
Uninterruptible power supply upon hot start Port priority |